Logger-Sycon_STM-100 -------------------- 2021-12-20: changed: reset_time() -> reset_timer 2021-03-26-r2: changed: Tooling and Density are represented by a text field so that the parameter syntax can be used. 2020-10-02: fixed: communication fixed for 1.5.5 (because of rstrip) added: actions "reset_thickness" and "reset_time" added changed: general revision of function structure and readAnswer method changed: checksum calculation in own method and messageBox if returned message is not ok. changed: tooling and density are read out only once during configure but not at each measurement point 2020-06-16: changed: Xtal life instead of Xtal used is shown 2019-10-18: tooling, density and Xtal are read out as return variables; improved reading of the COM port; channel selection; writing tooling and density if selected 2019-08-05-r1: description added: cross-over cable needed 2019-08-05: to work with python3 and pyserial, raw_read must be True 2019-06-23-r1: license file renewed 2019-06-23: first upload